Allmatic BIOS1 BRT Manual For Installation - Page 10
Browse online or download pdf Manual For Installation for Control Unit Allmatic BIOS1 BRT. Allmatic BIOS1 BRT 12 pages. Programmable control board for barriers brt
.. Flashing light output mode
It is possible to choose 2 different functioning for the blinker output:
.. = 0 Fixed blinker output. It will be necessary to connect a self flashing blinker (B.RO LIGHT 230 Vac)
.. = 1 Flashing light blinker output. It will be necessary to connect a fix light blinker (B.RO LIGHT FIX 230 Vac)
.. Pre-flashing time
Pre-flashing before each movement in both directions, .. seconds of pre-flashing
.. Courtesy light settings
The control unit has 4 different functionings for courtesy light:
.. = 0 the light switches off at the end of a movement after .. seconds
.. = 1 the light switches off only with closed barrier after .. seconds
.. = 2 lighted on for .. seconds from the beginning of a movement, indipendently of the condition of the barrier (the light could switch off
before the end of movement)
.. = 3 open barrier light - the light switches off immediately when the barrier reaches the closed position
.. = 4 open barrier light with proportional blinking:
opening – slow blinking
closing – fast blinking
opened – light on
closed – light off
stopped – 2flash + long wait + 2flash + long wait +...
.. Courtesy light timer
Courtesy light activation timer
.. Dead man
During dead man functioning mode the barrier moves only with a permanent command.
The enabled commands are OPEN and CLOSE. SS and PED are disabled. During dead man functioning all the automatic movements are disabled,
like short or total inversions. All safety devices are disabled except for STOP.
.. Setting threshold of cycles for assistance request
It is possible to set a number of cycles before the request of assistance. Once the limit is reached the next cycles will be done with fast blinking (only if
enabled)
.. Continuous flashing light for assistance request
Once limit .. is reached the flashing light will blink also with the barrier closed to show the request of assistance.
.. Viewing of the memory position for a single transmitter
With the item of the menu .. it is possible to view the memory location in which a transmitter is memorized.
To perform the function, move to .. and then confirm by pressing the button MENU. Keep pressed MENU button untill the display will show
then release the button.
At this point press a button of the memorized transmitter (it does not active any command). The display shows:
the memory location for 2 seconds, if is memorized;
the written
After 2 seconds the display returns to the screen
To exit from the function, press MENU button. Otherwise after 15 seconds without transmission, the control unit exits from the function and shows the
written
.. Cancellation of a single transmitter
With the item of the menu .. it is possible to delete a single transmitter from the memory.
To perform the function, move to .. and then confirm by pressing the button MENU. Keep pressed MENU button untill the display will show 0, then
release the button. Select the memory location of the transmitter. Press and keep pressed MENU button untill the display will show
release the button.
To exit from the function, press MENU button. If the display shows the written
position or disconnected memory).
.. Restore default settings
With this parameter it is possible to restore the default settings of the control unit. The reset will restore all the parameters of the base and advanced
menu, but doesn't modify the learned strokes, the directions of motors and the transmitters.
Move to .. then keep pressed MENU button until the display shows 0, release the button. Press again and keep pressed MENU button, the display
will show a count down ,,...,, do not release the button until the display showns
.. Erasing of all transmitters
With this parameter it is possible to erase all the transmitters learned.
Move to .. then keep pressed MENU button until the display shows 0, release the button. Press again and keep pressed MENU button, the display
will show a count down ,,...,. Do not release the button until the display showns
6-1622245
rev.3
23/12/2016
for 2 seconds, if is not memorized.
ITA
and it will be possible to perform this function with another transmitter.
, there are problems with the memory (for example empty
ENG
FRA
ESP
DEU
POR
, then