Allmatic BIOS2 Manual For Installation - Page 7

Browse online or download pdf Manual For Installation for Control Unit Allmatic BIOS2. Allmatic BIOS2 12 pages. Programmable control board for wings gates

Allmatic BIOS2 Manual For Installation

6.2 Advanced menu:

MENU
Functioning of opening photocell PHOTO2
.
.

0 = Enabled in opening and closing OP/CL
1 = Enabled only in opening OP
Photocells test
0 = disabled
.
.

1 = enabled PHOTO1
2 = enabled PHOTO2
3 = enabled PHOTO1 and PHOTO2
Safety edge type
.
.


0 = contact (NC)
1 = resistive (8k2)
Operation mode of safety edge
0= working only in closing with inversion of movement
.
.


1 = stops the automation (both opening and closing) and free the obstacle (short
inversion)
Safety edge test
.
.


0 = disabled
1 = enabled
.
.


Pedestrian opening
.
.


Auto reclosing time from pedestrian opening (0 = disabled)
Blinker output mode
.
.


0 = Fix
1 = Blinking
.
.


Pre-flashing time (0 = disabled)
Courtesy ligth settings
0 = At the end of movement for a TCY time
1 = On if the gate is not closed + TCY time
.
.


2 = On if courtesy light timer (TCY) not expired
3 = Open gate light on/off
4 = Open gate light with proportional flashing
.
.


Courtesy light time
Dead-man
.
.


0 = disabled
1 = enabled
Setting threshold of cycles for assistance request. Once limit is reached the next
.
.


cycles will be done with fast blinking (only if  enabled) (0 = disabled)
Continuous blinking for assistance request (done only with closed gate).
.
.


0 = disabled
1 = enabled
.
.


Water-hammer and elecrtical lock in opening phase (0 = disabled)
.
.


Water-hammer in closing phase (0 = disabled)
.
.


Time of pressure in closed for hydraulic motors (0 = disabled)
Viewing of the memory location for a single transmitter
Cancellation of a single transmitter
Restore default settings, enter to modify the parameter and then keep pressed the
.
.


MENU button, a count down appears that ends with  on the display
Cancelling all transmitters, enter to modify the parameter and then keep pressed
.
.


the MENU button, a count down appears that ends with  on the display
6-1622189
rev.1
22/05/2015
DESCRIPTION
ITA
ENG
FRA
SELECTABLE
ESP
DEU
POR
VALUES
DEFAULT
min-max
0-1
0
0-3
0
0-1
0
0-1
0
0-1
0
0-100
30
0-900
20
0-1
1
0-10
0
0-4
0
0-900
0
0-1
0
0-100
0
0-1
0
0-100
0
0-100
0
0-480
0
0-999
0-999
UNITS
%
s
s
s
x1000
cicli
x100
ms
x100
ms
minuti
7 / 12