Miele 09 968 280 Operating And Installation Instructions - Page 27

Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele 09 968 280. Miele 09 968 280 36 pages. Ventilation hood da 5996 w miele

Miele 09 968 280 Operating And Installation Instructions
a Vented
b Recirculation
c Air outlet positioned at top for recirculation
de (only d is required for recirculation mode hoods): The shaded area
represents the wall or ceiling area for the vent cut-out, for fitting the
connection socket and on EXT models for feeding the connection cable
through to the external motor. Recirculation mode range hoods only require
an electrical connection socket.
 Existing tiling or a back panel behind the hood can make it difficult to remove
the grease filter. If this is the case, turn the filter by 180° and fit it before the range
hood is installed .
Exhaust connector  6" (150 mm), with reducer  5" (125 mm).
Installation
27