Miele AWG 102 Operating And Installation Instructions
MG 100
* Extends from 280 – 390 mm
a Equipotential bonding
The MG 100 motor is designed for
installation inside an external wall.
The external motor is connected to the
cooker hood by means of a control
cable and is operated by the control
panel on the cooker hood.
Please refer to the operating and
installation instructions for the
cooker hood, before installing the
external motor and ducting.
^ Make a hole 280 mm wide x 240 mm
deep through the wall.
^ Extend the size of the hole on the
outside wall side, downwards to
make it 365 mm high and into the
wall to a depth of approx. 150 mm.
^ Use a crosstip screwdriver to remove
the screws from the appliance cover
A and take off the cover.
^ Screw brackets B supplied by the
angled section to the housing frame
from behind (see illustration).
^ Mark the drill hole positions for
brackets B on the brickwork.
Installation
11