The external motor is connected to the
rangehood by means of a special
control cable and is operated by the
touch controls on the rangehood.
The electrical system and connection of
this appliance must comply with
national and local safety regulations.
For extra safety, it is advisable to
protect the appliance with a suitable
residual current device (RCD) with a trip
current of 30 mA.
The relevant connection data can be
found on the data plate (see "After sales
service and warranty"). Ensure that this
data matches the voltage and
frequency of your household mains
supply.
The external motor is supplied with a
5 m extension cable. If the control
cable needs to be extended further
by means of an additional extension
cable or a hardwired connection
cable (at least 6 x 1.5 mm²), the
installation must be carried out in
strict accordance with local and
national safety regulations.
Equipotential bonding is required in
this case.
The external motor is supplied with
an earthed connection point .
This external motor has been
designed to be connected to a Miele
rangehood only and must not be
connected to a rangehood made by
another manufacturer.