Miele DA 1060 Operating And Installation Instructions - Page 26

Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 1060. Miele DA 1060 40 pages.

Installation

Safety distance (S)

The minimum distances between the highest part of a cooktop (including
trivets, dials - depending on model) and the bottom of the rangehood are as
follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h total output,
with no burner having a greater output than 16.2 MJ/h.
Multi-burner gas cooktop with total output greater than 45.4 MJ/h,
but with a maximum of 77.8 MJ/h, with no burner having a greater
output than 17.3 MJ/h.
Multi-burner gas cooktop with total output greater than 77.8 MJ/h,
with a single burner having a greater output than 17.3 MJ/h.
Single burner gas cooktop with a maximum output of 21.6 MJ/h.
Single burner gas cooktop with an output greater than 21.6 MJ/h,
but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater than 29.2 MJ/h.
26
Minimum
distance S
600 mm
650 mm
650 mm
760 mm
Not
possible
650 mm
760 mm
Not
possible