Installation
Safety distance (S)
The minimum distances between the highest part of a cooktop (including
trivets, dials - depending on model) and the bottom of the rangehood are as
follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h total output,
with no burner having a greater output than 16.2 MJ/h.
Multi-burner gas cooktop with total output greater than 45.4 MJ/h,
but with a maximum of 77.8 MJ/h, with no burner having a greater
output than 17.3 MJ/h.
Multi-burner gas cooktop with total output greater than 77.8 MJ/h,
with a single burner having a greater output than 17.3 MJ/h.
Single burner gas cooktop with a maximum output of 21.6 MJ/h.
Single burner gas cooktop with an output greater than 21.6 MJ/h,
but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater than 29.2 MJ/h.
26
Minimum
distance S
600 mm
650 mm
650 mm
760 mm
Not
possible
650 mm
760 mm
Not
possible