Miele DA 1200 Operating And Installation Instructions - Page 20
Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 1200. Miele DA 1200 48 pages.
Cleaning and care
Important for the controls
Do not leave soiling on the controls
for any length of time.
Otherwise they may suffer
discolouration or damage.
Remove soiling straight away.
Please observe the general notes on
cleaning earlier in this section.
Do not use stainless steel cleaning
agents on the controls.
Grease filters
Fire hazard!
Oversaturated grease filters are a fire
hazard.
Clean the grease filters at regular
intervals.
The re-usable metal grease filters in the
appliance remove solid particles
(grease, dust, etc.) from the kitchen
vapours, preventing soiling of the
cooker hood.
The grease filters must be cleaned at
regular intervals.
Heavily soiled grease filters hinder air
extraction and will lead to increased
levels of soiling in the cooker hood
and in the kitchen.
20
Cleaning interval
Accumulated grease solidifies over a
longer period of time and makes
cleaning more difficult. The grease
filters should therefore be cleaned every
3 to 4 weeks.
Removing a grease filter
When handling a grease filter, be
careful not to drop it.
This can result in damage to the filter
and the hob below.
Make sure you hold the filter securely
at all times when handling it.
To take out a grease filter, release the
locking clip on the filter, lower the
filter approx. 45°, unhook it at the
back and remove it.
Cleaning the grease filters by hand
Clean the filters with a soft nylon
brush in a mild solution of hot water
and a small amount of washing-up
liquid. Do not use "neat" washing up
liquid.