 Attach the exhaust ducting, e.g.
flexible hose, to the exhaust socket
using a hose clip (available as an
optional accessory).
 Insert the exhaust socket into the
exhaust opening and secure it by
turning it slightly clockwise.
 See "Connection for air extraction"
for further instructions on fitting the
ducting.

For recirculation mode

 Fit the charcoal filter (see "Cleaning
and care").

Electrical connection

Refer to the notes in "Electrical
connection" and "Warning and
Safety instructions" before
connecting to the electricity supply.
 Connect the cooker hood to the
electricity supply.

Functional check

 To do this, switch the fan on.
– In air extraction mode air should not
come out of the recirculation grille at
the front of the cooker hood.
– In recirculation mode the air should
come out of the recirculation grille at
the front of the cooker hood.
If this does not happen, the deflector is
not installed correctly (see "Deflector").
Installation
37