Installation
Wall installation
The cooker hood is fitted to the wall
inbetween two wall units. Screws and
plugs are supplied for this.
Cut the drilling template to size and
position against the wall. The top
edge of the template indicates the
top edge of the cooker hood. Please
observe the safety distance (S) to the
hob (see "Appliance dimensions").
Mark and drill four holes for the fixing
brackets ( 8 mm).
Remove the drilling template.
Secure the fixing brackets to the wall
using the plugs and screws supplied.
The screws and plugs are
designed for use in solid walls only.
For other types of wall construction,
alternative fixings will be required.
Make sure the wall is able to take the
weight of the cooker hood.
Attach the corresponding drilling
template to the adjacent cabinet or
the side panel.
Drill two holes into the adjacent
cabinet or the side panel ( 2 mm).
26
Remove the recirculation grille for
extraction mode.
Hang the cooker hood into position
using the adjustable brackets.