Miele DA 2250 EXT Operating And Installation Instructions - Page 39
Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 2250 EXT. Miele DA 2250 EXT 40 pages. Cooker
Also for Miele DA 2250 EXT: Operating And Installation Manual (40 pages), User Manual (40 pages), Operating And Installation Instructions (40 pages)
Connected load* . . . . . . . . . . . . . 280 W
Fan motor* . . . . . . . . . . . . . . . . . 180 W
Hob lighting . . . . . . . . . . . . . . 2 x 50 W
Voltage . . . . . . . . . . . . . . . . . AC 230 V
Frequency . . . . . . . . . . . . . . . . . . 50 Hz
Fuse rating (UK) . . . . . . . . . . . . . . . . 5 A
Electrical cable length . . . . . . . . . 1.5 m
Weight
DA 3160 . . . . . . . . . . . . . . . . . . . . 12 kg
DA 3160 EXT . . . . . . . . . . . . . . . . 10 kg
DA 3190 . . . . . . . . . . . . . . . . . . . . 14 kg
DA 3190 EXT . . . . . . . . . . . . . . . . 12 kg
Fan performance*
Extraction power according to EN 61591
Extraction system ø 150 mm:
Level I . . . . . . . . . . . . . . . . . . . 150 m
Level II. . . . . . . . . . . . . . . . . . . 275 m
Level III . . . . . . . . . . . . . . . . . . 400 m
Intensive Setting . . . . . . . . . . . 550 m
Recirculation with charcoal filter:
Level I . . . . . . . . . . . . . . . . . . . . 80 m
Level II. . . . . . . . . . . . . . . . . . . 180 m
Level III . . . . . . . . . . . . . . . . . . 280 m
Intensive Setting . . . . . . . . . . . 350 m
Optional accessories for
recirculation mode:
- Conversion Kit DUU 151
- Miele charcoal filter DKF 13-1
* For EXT models the connected load
and extraction power will depend on
the type of external motor fitted.
EXT models:
Length of connection cable to external
motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
Technical data
39