Preparation for extraction
^ The cooker hood is designed to
operate with C 150 mm exhaust
ducting. If C 125 mm exhaust
ducting has to be used, the adapter
supplied must be used (see
"Connection for air extraction").
Fit the adapter to the exhaust socket
before installing the ducting.
DA 2210: The hood has two exhaust
connections for use with two 150 mm
diameter exhaust hoses.
A Y- adapter is supplied with the
hood. It may be used to feed the
exhaust from both connections to a
200 mm diameter common duct.
^ Secure the vent ducting to the
exhaust socket with a hose clip and
connect to the venting system (see
"Connection for air extraction").
Recirculation
1 0
If site conditions are not suitable for the
cooker hood to be used with air
extraction, the appliance must be set
up for recirculation.
For this, conversion kit DUU 151
(available from your Miele dealer or the
Miele Spare Parts Dept.) is required.
One conversion kit is required for the
DA 2250 and 2270, and two kits for the
DA 2210.
You will also require two charcoal filters
for the DA 2250 and 2270, or 4
charcoal filters for the DA 2210 (see
"Technical data").
Installation
4 0
1 6
3 3
0