a Alternative vent connection at the back.
b The cooker hood is fastened in the cut-out using clamps. A solid installation
surface, e.g. made of wood, is required. Make sure that the structure can
support the load. Around the clamps, components such as supports and
ducting must be at least 25 mm from the cut-out.
c Alternatively, the cooker hood can be secured to 4 fixing points on an interim
shelf.
d Additional fixing points on the installation surface.

Safety distance between hob and cooker hood (S)

When planning the installation height of your cooker hood, the minimum safety
distance between the top of a cooker or hob and the bottom of the cooker hood
is as follows, unless a greater distance is specified by the manufacturer of your
cooking appliance.
See "Warning and Safety" instructions for further information.
Cooking appliance
Electric hob
Electric grill, deep fat fryer (electric)
Multi-burner gas hob,
total output ≤ 12.6 kW, no burner > 4.5 kW
Multi-burner gas hob,
total output > 12.6 kW and ≤ 21.6 kW,
no burner > 4.8 kW.
Multi-burner gas hob,
total output > 21.6 kW,
or multi-burner gas hob where one burner > 4.8 kW.
Single burner gas hob, output ≤ 6 kW.
Single burner gas hob, output > 6 kW and ≤ 8.1 kW.
Single burner gas hob, output > 8.1 kW
Installation
Minimum distance S
450 mm
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible