Cooking process
If, for example, you switch on a
cooking zone at the highest power
setting to heat a pan for frying and
reduce the power level after approx.
60 to 90 seconds*, a cooking process
is recognised (*60 seconds to 5
minutes for a HiLight cooktop).
The rangehood switches itself on and
when the cooktop power level has been
reduced, the rangehood switches to
power setting 3 and remains at that
level for approx. 5 minutes.
After that the rangehood power setting
is determined automatically by the
Con@ctivity function.
You can select another power setting
manually before then.
Operation (automatic mode)
Switching off
Switch off all cooking zones.
The rangehood fan will reduce its power
level in stages over the next few
minutes and will then switch itself off.
This helps to neutralise any lingering
vapours and odours in the air.
– From the Booster setting, the fan
switches immediately to level 3.
– From level 3, it will switch to level 2
after approx. 1 minute.
– From level 2, it will switch to level 1
after 2 minutes.
– After 2 minutes at Level 1, the fan
switches itself off.
– After another 30 seconds, the
cooktop lighting switches off.
The cooking process is then finished.