Miele DA 270-4 Operating And Installation Instructions - Page 13
Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 270-4. Miele DA 270-4 36 pages. Ventilation system
Also for Miele DA 270-4: Operating And Installation Instructions (32 pages), Product Dimensions (2 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (32 pages)
To switch the fan on
^ Press the On/Off control.
The fan runs at power level "II". The
indicator lamp will come on.
If the cooker hood has been
connected to a window contact
switch via the Miele DSM 400 control
module, then the fan cannot be
switched on if the window is shut.
The indicator lamp will flash.
To select a power level
^ Use the - / + controls to select the
power level required.
+ control = higher setting
- control
= lower setting
Depending on the intensity of the
cooking vapours, levels I to III (green
indicator lamps) are usually sufficient
for normal cooking.
Intensive setting
When frying or cooking food with a
strong aroma, you may wish to select
the Intensive setting, level IV (yellow
indicator lamp) for a short period.
Automatic switch-off of the Intensive
setting
You can set the Intensive setting so that
it only runs for 10 minutes before
reverting automatically to level III.
^ To set this option, both the fan and
the hob lighting must be switched off.
^ Press the run-on option control for
approx. 10 seconds. The first fan
setting indicator will light up.
^ Then press in turn,
– the right-hand lighting control,
– the - control, and
– the right-hand lighting control again.
Operation