Miele DA 289-4 Operating And Installation Manual - Page 18

Browse online or download pdf Operating And Installation Manual for Ventilation Hood Miele DA 289-4. Miele DA 289-4 40 pages. Cooker
Also for Miele DA 289-4: Operating And Installation Instructions (36 pages), Install Manual (1 pages), Operating And Installation Manual (36 pages), Operating And Installation Instructions (36 pages)

Miele DA 289-4 Operating And Installation Manual
Operation

Filter operating hours counter

The number of hours the appliance has
been in operation is stored in memory.
The indicator lamp for the grease filter
control will come on after 30 hours of
operation. The vapour plate and the
grease filter must then be cleaned.
Afterwards, the operating hours counter
must be reset.
^ To do this, press and hold the grease
filter control for about 3 seconds.
The indicator lamp for the grease filter
control will go out.
Reading the filter operating hours
counter
To check the percentage of time set
already used:
^ Press the On/Off control to switch the
fan on.
^ Press the grease filter control.
18
One or more of the indicator lamps for
the – /+ controls will flash.
The number of flashing lamps shows
the percentage of the operating time
which has already been used up.
1 lamp
= 25 %
2 lamps = 50 %
3 lamps = 75 %
4 lamps = 100 %
The number of operating hours used
remains in the memory, even when the
appliance is switched off or there is a
power cut.