a 3 protective sheets
for use when fitting the tower.
b Upper retaining plate
for securing the extension piece.
c Middle retaining plate
for securing the extension piece.
d 2 hose clips
for securing the exhaust ducting.
e 1 reducing collar
for exhaust ducting C 125 mm (not
on ...EXT models).
f 1 non-return valve
for fitting into the exhaust socket on
the motor unit (not on ...EXT models).
5 large headed screws 5 x 40 mm and
5 x S 8 plugs
for securing the retaining plates and the
appliance unit.
2 screws 5 x 60 mm and
2 x S 8 R 60 plugs
for securing the appliance unit.
The screws and plugs are designed
for use in solid walls only.
For other types of wall construction,
alternative fixings will be required.
Make sure that the wall is able to
take the weight of the cooker hood.
6 screws 3.5 x 9.5 mm
for securing the canopy and the filter
housing
2 cover caps
1 lever
for changing the halogen lamp and
dismantling the tower
Installation instructions
Installation
25