Miele DA 3060 Operating And Installation Manual - Page 17
Browse online or download pdf Operating And Installation Manual for Ventilation Hood Miele DA 3060. Miele DA 3060 36 pages. Cooker
Also for Miele DA 3060: Operating And Installation Instructions (36 pages)
1) The front section of the wall housing
unit must be fitted with a shelf to the
depth of the partition wall.
2) The partition wall in the wall unit must
be removable.
3) In extraction mode: when measuring
for the height of the wall housing unit
and the cut-out, account must be taken
of any accessories fitted, e.g. silencer.
4) Recirculation mode requires
installation kit DUU 151.
Appliance dimensions
Safety distance between hob and
cooker hood
The minimum safety distances
between the top of a cooker or hob
and the bottom of the cooker hood
are as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
– 450 mm (GB), 600 mm (AU, NZ)
above electric hobs and cookers,
– 650 mm above an open grill or
deep fat fryer,
– 650 mm above gas hobs and
cookers.
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
See "Warning and Safety
instructions" for further information.
17