Connected load* . . . . . . . . . . . . . 280 W
Fan motor* . . . . . . . . . . . . . . . . . 180 W
Hob lighting . . . . . . . . . . . . . . 2 x 50 W
Voltage . . . . . . . . . . . . . . . . . AC 230 V
Frequency . . . . . . . . . . . . . . . . . . 50 Hz
Fuse rating (UK) . . . . . . . . . . . . . . . . 5 A
Electrical cable length . . . . . . . . . 1.5 m
Weight
DA 3160 . . . . . . . . . . . . . . . . . . . . 12 kg
DA 3160 EXT . . . . . . . . . . . . . . . . 10 kg
DA 3190 . . . . . . . . . . . . . . . . . . . . 14 kg
DA 3190 EXT . . . . . . . . . . . . . . . . 12 kg
Fan performance*
Extraction power according to EN 61591
Extraction system ø 150 mm:
Level I . . . . . . . . . . . . . . . . . . . 150 m
Level II. . . . . . . . . . . . . . . . . . . 275 m
Level III . . . . . . . . . . . . . . . . . . 400 m
Intensive Setting . . . . . . . . . . . 550 m
Recirculation with charcoal filter:
Level I . . . . . . . . . . . . . . . . . . . . 80 m
Level II. . . . . . . . . . . . . . . . . . . 180 m
Level III . . . . . . . . . . . . . . . . . . 280 m
Intensive Setting . . . . . . . . . . . 350 m
Optional accessories for
recirculation mode:
- Conversion Kit DUU 151
- Miele charcoal filter DKF 13-1
* For EXT models the connected load
and extraction power will depend on
the type of external motor fitted.
EXT models:
Length of connection cable to external
motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
3
/h
Technical data