Miele DA 3180 Operating And Installation Instructions - Page 6

Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 3180. Miele DA 3180 40 pages. Ventilation system
Also for Miele DA 3180: Operating And Installation Instructions (36 pages), Dimensions (1 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (40 pages)

Miele DA 3180 Operating And Installation Instructions
Warning and Safety instructions
~
Do not connect the appliance to the
mains electricity supply by a
multi-socket unit or an extension lead.
These do not guarantee the required
safety of the appliance (e.g. danger of
overheating).
~
For appliances with an external fan
motor fitted (...EXT models) the
connection of the two units must be
made using the connection cable and
the plug connectors.
These models may only be combined
with a Miele external motor.
~
This appliance must not be used in
a non-stationary location (e.g. on a
ship).
~
In areas which may be subject to
infestation by cockroaches or other
vermin, pay particular attention to
keeping the appliance and its
surroundings in a clean condition at all
times. Any damage which may be
caused by cockroaches or other vermin
will not be covered by the guarantee.
6
Using at the same time as other
heating appliances that depend on
the air from the room
Warning - danger of toxic fumes
~
Great care should be taken when
using the cooker hood at the same time
and in the same room or area of the
house as another heating appliance
which depends on the air in the room.
Such appliances include gas, oil, wood
or coal-fired boilers and heaters,
continuous flow or other water heaters,
gas hobs, cookers or ovens which draw
air in from the room and duct exhaust
gases out through a chimney or
extraction ducting.
When used in extraction mode, with or
without an external motor fitted, the
appliance draws air in from the room in
which it is installed and from
neighbouring rooms.
If there is insufficient air, an
underpressure will occur. The heating
appliance may be starved of oxygen,
impairing combustion.
Harmful gases could be drawn out of
the chimney or extraction ducting back
into the room, with potentially fatal
consequences.