Changing a halogen lamp

^ Pull out the deflector plate, and
remove the grease filter as described
earlier.
^ Switch off the fan and the lighting.
,
Exercise caution when changing
halogen lamps. They get very hot
during use, and remain hot for some
time after being switched off. Do not
touch the surface directly when
changing a lamp, as grease
particles from your fingers will
adhere to the surface and damage
it. Please follow the manufacturer's
instructions.
^ Remove the charcoal filter if the
cooker hood is being used in
recirculation mode.
Before any cleaning or maintenance
work, disconnect the cooker hood
from the mains supply.
Cleaning and care
^ Push down the lighting unit slightly
via the opening in the safety panel.
^ The halogen lamp is now accessible
to be unscrewed anti-clockwise.
^ Replace it with a new halogen lamp
(specification: GU/GZ 10, 230 V,
50 W). Screw the lamp into the
socket and push it upwards.
Please follow the manufacturer's
instructions.
^ Replace the grease filter and, if being
used in recirculation mode, the
charcoal filter.