Miele DA 3480 Installation Instructions Manual - Page 18

Browse online or download pdf Installation Instructions Manual for Ventilation Hood Miele DA 3480. Miele DA 3480 24 pages. Ventilation system
Also for Miele DA 3480: Operating And Installation Manual (40 pages), Operating And Installation Manual (40 pages)

Miele DA 3480 Installation Instructions Manual
– If the exhaust is ducted into an
inactive flue, the air must be expelled
parallel to the flow direction of the
flue.
Never connect an exhaust hood to
an active chimney, dryer vent, flue,
or room venting ductwork. Seek
professional advice before
connecting an exhaust hood vent to
an existing, inactive chimney or vent
flue.
Important
If the ductwork runs through rooms,
ceilings, garages, etc. where
temperature variations exist, it may
need to be insulated to reduce
condensation.

Condensate trap

optional accessory
In some cases, a condensate trap may
also be required to collect and
evaporate any condensate which may
occur. This optional accessory is
available for ducts 5" (125 mm) and 6"
(150 mm) in diameter.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust outlet.
Air extraction
35