Appliance dimensions
DA 3490
1) The front section of the wall housing
unit must be fitted with a shelf to the
depth of the partition wall.
If the appliance is fitted further back,
e.g. to accomodate a front panel, then
the shelf depth should be
correspondingly deeper.
2) The partition wall in the wall unit must
be removable.
3) In extraction mode: when measuring
for the height of the wall housing unit
and the cut-out, account must be taken
of any accessories fitted, e.g. silencer,
DSM module.
22
4) Recirculation mode requires
installation kit DUU 151.
5) Optional DSM 400
* Installation is also possible in a
600 mm wide unit.
* Installation is also possible in a
762 mm wide unit.
Safety distance between hob and
cooker hood
The following distance must be
maintained between the top of the
cooker/hob and the bottom of the
cooker hood unless a greater
distance is specified by the
manufacturer of the cooker or hob:
above electric hobs and cookers
450 mm
above electric barbecue grilles and
deep fat fryers 650 mm
above gas hobs and cookers
650 mm
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
See "Warning and Safety
instructions" for further information.