Cleaning and care
Changing a lamp
The lamps should be replaced with the
following:
Manufacturer ............................... EGLO
Lamp type .................................... GU10
Specification................................ 12981
Wattage ........................................... 3 W
These lamps are available from Miele or
from specialist retailers.
Pull out the deflector plate, and
remove the grease filter as described
earlier.
Switch off the fan and the lighting.
Note that lamps become hot
when in use.
Allow the lamps to cool down for a
few minutes before changing them.
Remove the charcoal filter if the
rangehood is being used in
recirculation mode.
Disconnect the rangehood from the
mains electrical supply before
replacing the lamps (see "Warning
and Safety instructions").
24
Push down the lighting unit slightly
via the opening in the safety panel.
Turn the lamp anti-clockwise and pull
it out.
Screw the new lamp into the socket
and push it upwards. Please follow
the manufacturer's safety
instructions.
Replace the grease filter and, if being
used in recirculation mode, the
charcoal filter.