Miele DA 3496 EXT Operating And Installation Instructions - Page 38
Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 3496 EXT. Miele DA 3496 EXT 48 pages.
Also for Miele DA 3496 EXT: Operating And Installation Instructions (48 pages)
Installation
Set up for recirculation mode
If site conditions are not suitable for the
rangehood to be used with air
extraction, the appliance must be set
up for recirculation. The DUU 151
conversion kit, available from Miele, is
required for operating the rangehood in
recirculation mode. You will also need a
charcoal filter (see "Technical data").
When using the rangehood in
recirculation mode, a non-return flap is
not fitted. Depending on the model of
rangehood, the non-return flap may
already be fitted.
Remove the non-return flap from the
exhaust connection.
38
Fit the conversion kit as described in
the installation instructions supplied
with the kit. Make sure that the slats
in the exhaust grille point towards the
centre of the room and not towards a
wall or the ceiling.
A non-return flap is not used in
recirculation mode.
Fit the charcoal filter (see "Cleaning
and care").