a Extraction
b Recirculation
c Ventilation grille positioned at the top for recirculation
de (only d is required for recirculation mode rangehoods): The shaded area
represents the wall or ceiling area for the vent cut-out, for fitting the
connection socket and on EXT models for feeding the connection cable
through to the external motor. Recirculation mode rangehoods only require
an electrical connection socket.
Connection for air extraction 150 mm, or 125 mm with reducing collar.
Safety distance (S)
The minimum distances between the top of a cooktop (excluding trivets, dials -
depending on model) and the bottom of the rangehood are as follows, unless a
greater distance is specified by the manufacturer of your cooking appliance.
See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Open electric grill
Deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h
total output, with no burner having a greater output than
16.2 MJ/h.
Multi-burner gas cooktop with total output greater than
45.4 MJ/h, or a gas cooktop including a single burner
with an output greater than 16.2 MJ/h.
Single gas cooktop with a maximum output of 21.6
MJ/h.
Single gas cooktop with a maximum output greater
than 21.6 MJ/h.
Installation
Minimum distance S
600 mm
650 mm
650 mm
650 mm
760 mm
650 mm
760 mm
27