Miele DA 399-7 Operating And Installation Instructions - Page 34
Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DA 399-7. Miele DA 399-7 40 pages.
Also for Miele DA 399-7: Operating And Installation Instructions (36 pages), Operating And Installation Instructions (40 pages)
Connection for air extraction
Recirculation mode
The silencer needs to be positioned
between the exhaust connection and
the directional unit . Ensure there is
adequate space in the tower for fitting
it.
Air extraction with external motor
To minimise noise from the motor in the
kitchen, the silencer should be
positioned in front of the external motor
if possible, or, if the ducting is long,
above the exhaust connection inside
the rangehood . In the case of an
external motor located inside the house,
fitting a silencer behind the external
motor reduces the noise of the motor
outside the house.
34