Also for Miele DA 409: Operating And Installation Instructions (36 pages), Installation Instructions (1 pages), Product Dimensions (2 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages)

Miele DA 409 Operating And Installation Manual
Cleaning the grease filters by hand
^ Clean the filters with a soft nylon
brush in a mild solution of hot water
and a little washing-up liquid.
Do not use:
– cleaning agents containing
descaling agents,
– powder cleaners, cream cleaners or
abrasive all-purpose cleaning
agents,
– oven sprays.
Cleaning the grease filters in the
dishwasher
^ Place the filters as upright as
possible in the lower basket, with the
short sides upright, and wash on a
65°C programme, ensuring the spray
arm is not obstructed. If a Miele
dishwasher is being used, select the
Sensor wash programme.
^ Use a mild dishwasher detergent.
Depending on the cleaning agent
used, cleaning the filters in a
dishwasher can cause permanent
discolouration to the surface.
However, this will not affect the
functioning of the filters in any way.
^ After cleaning, leave the filters to dry
on an absorbent surface before
replacing them.
When removing the filters for cleaning,
also clean off any residues of oil or fat
from the now accessible housing to
prevent the risk of these catching fire.
Cleaning and care
When putting the grease filters back in
position, ensure that the locking clips
are facing down towards the hob.
If the grease filters are inadvertently
replaced upside down, insert a small
screwdriver blade into the slits to
disengage the clip.
^ After replacing the grease filter,
press the grease filter touch control
for approx. 3 seconds to re-set the
operating hours counter.
The indicator lamp will go out.
If the grease filters are cleaned before
the operating hours counter has
reached its maximum, the grease filter
touch control should be pressed for
approx. 6 seconds to reset the counter.