Also for Miele DA 409: Operating And Installation Instructions (36 pages), Installation Instructions (1 pages), Product Dimensions (2 pages), Operating And Installation Manual (40 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages), Operating And Installation Instructions (36 pages)

Miele DA 409 Operating And Installation Instructions
All electrical work should be
undertaken by a suitably qualified
and competent person in strict
accordance with national and local
safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous, for which the
manufacturer cannot be held liable.
Ensure power is not supplied to the
appliance until after installation or
repair work has been carried out.
Do not connect the appliance to the
mains electricity supply by an
extension lead. These do not
guarantee the required safety of the
appliance.
when the grease filters have been
removed. Ensure that these match the
household mains supply.
Connection of this appliance should be
made via a suitable isolator or a double
pole fused spur connection unit which
complies with national and local safety
regulations and the On-Off switch
should be easily accessible after the
appliance has been built in.
When switched off there must be an
all-pole contact gap of 3 mm in the
switch (including switch, fuses and
relays according to EN 60 335).
If the switch is not accessible after
installation (depending on country), an
additional means of disconnection must
be provided for all poles.
. This is visible
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA.
U.K., IRL, NZ, ZA: This appliance is
supplied for connection to an a.c.
230 V single phase 50 Hz supply.
AUS: This appliance is supplied for
connection to an a.c. single phase
240 V, 50 Hz supply.
The wires in the mains lead are
coloured in accordance with the
following code:
Green/yellow = earth
Blue
= neutral
Brown
= live