Cleaning and care
Changing a halogen lamp
To change the lamps, the canopy
needs to be open.
^ Touch the s sensor.
The fan will start running at power level
2, and the canopy will open.
^ Touch the "2" sensor for approx. 5
seconds, until the fan switches off.
The canopy will remain open.
^ Before any cleaning or maintenance
work, disconnect the cooker hood
from the mains supply. Ensure that:
– it is switched off at the isolator, or
– the screw-out fuse is removed (in
countries where this is applicable), or
– the fuse from the fused spur
connection unit is withdrawn, or
– it is switched off at the mains fuse
box.
^ Remove the grease filters.
,
Exercise caution when changing
halogen lamps. They get very hot
during use, and remain hot for some
time after being switched off: danger
of burning.
Wait until the lamps have cooled
down before changing them.
20
^ Press the lighting unit down slightly
through the hole above the lamp, as
shown.
^ Turn the halogen lamp anti-clockwise
out of its socket.
^ Replace it with a new halogen lamp
(specification: GU/GZ 10, 230 V, 50
W, 50°). Screw the lamp into the
socket and push it upwards.
We recommend only using lamps of the
same specification and also made by
the same manufacturer as the ones
being replaced.
^ Replace the grease filters.
^ Reconnect the cooker hood to the
mains supply.