Miele DAR 1220 Operating And Installation Instructions - Page 30

Browse online or download pdf Operating And Installation Instructions for Ventilation Hood Miele DAR 1220. Miele DAR 1220 40 pages. Range wall / insert hood
Also for Miele DAR 1220: Operating And Installation Instructions (32 pages), Operating And Installation Instructions (22 pages), Operating And Installation Instructions (40 pages)

Miele DAR 1220 Operating And Installation Instructions
Installation

Safety distance (S)

The minimum distances between the highest part of a cooktop (including
trivets, dials - depending on model) and the bottom of the rangehood are as
follows, unless a greater distance is specified by the manufacturer of your
cooking appliance. See also "Warning and Safety instructions".
Cooking appliance
Electric cooktop
Electric grill, deep fat fryer (electric)
Multi-burner gas cooktop with maximum 45.4 MJ/h total
output, with no burner having a greater output than
16.2 MJ/h.
Multi-burner gas cooktop with total output greater than
45.4 MJ/h, but with a maximum of 77.8 MJ/h, with no
burner having a greater output than 17.3 MJ/h.
Multi-burner gas cooktop with total output greater than
77.8 MJ/h, with a single burner having a greater output
than 17.3 MJ/h.
Single burner gas cooktop with a maximum output of
21.6 MJ/h.
Single burner gas cooktop with an output greater than
21.6 MJ/h, but with a maximum of 29.2 MJ/h.
Single burner gas cooktop with an output greater than
29.2 MJ/h.
30
Minimum distance S
600 mm (AU, NZ)
450 mm (HK, MY, SG)
650 mm
650 mm
760 mm
Not possible
650 mm
760 mm
Not possible