In recirculation mode, the silencer
needs to be positioned between the ex-
haust socket and the directional unit .
Check that there is sufficient space.

Electrical connection

The cooker hood is supplied with a
mains cable with moulded plug ready
for connection to a suitable earthed
socket.
If the socket is not easily accessible or
a fixed connection is envisaged, ensure
that a suitable means of disconnection
is provided on the installation side for
each pole.
Risk of fire from overheating.
Connecting the cooker hood to
multi-socket adapters or extension
cables can overload the cables.
For safety reasons, do not use an ex-
tension cable or multi-socket ad-
apter.
The electrical system must comply with
local and national safety regulations
(BS 7671 in the UK).
For safety reasons, we recommend us-
ing a type  residual current device
(RCD) in the relevant electrical installa-
tion for connecting the cooker hood.
If the mains connection cable is dam-
aged, it must only be replaced with a
specific mains connection cable of the
same type (available from the Miele
Customer Service Department). For
safety reasons, such replacement may
only be carried out by a qualified spe-
cialist or the Miele Customer Service
Department.
These operating instructions and the
data plate indicate the nominal power
consumption and the appropriate fuse
rating. Compare this information with
the data of the on-site electrical con-
Installation