Miele Imperial DIF 976 EX Operating And Installation Manual - Page 23

Browse online or download pdf Operating And Installation Manual for Ventilation Hood Miele Imperial DIF 976 EX. Miele Imperial DIF 976 EX 32 pages.

Miele Imperial DIF 976 EX Operating And Installation Manual
Electrical connection
All electrical work should only be under-
taken by a suitably qualified and com-
petent person in strict accordance with
national and local safety regulations.
The cooker hood is supplied for con-
nection to a 220-230 V single phase
50 Hz supply.
The data plate gives the necessary
data for connection. This is visible
when the grease filter has been
removed.
Connection should be made by a
double pole fused spur connection unit
and the On-Off switch should be easily
accessible after the appliance has
been built in.
When switched off there must be an all-
pole contact gap of 3 mm in the switch
(including switch, fuses and relays ac-
cording to EN 60 335).
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA (in accordance
with DIN VDE 0664).
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live.
23