Installation

Safety regulations prohibit the fitting
of this cooker hood over a solid fuel
stove.
The minimum safe distance be-
tween the top of the cooker/hob and
the bottom of the cooker hood
should be at least:
450 mm above electric
cookers/hobs
650 mm above gas cookers/hobs
650 mm above an open grill.
A distance of 650 mm above elec-
tric cookers/hobs may be prefer-
rable to give more working space.
See "Warning and Safety instructions"
for further notes on safe installation.
20
H = 770 – 1000 mm
When venting to the rear through the
wall the minimum height is 825 mm.
Maintain a minimum distance "a" be-
tween the top of the hood chimney and
the ceiling of 2 cm, so that the hood
chimney can be removed if necessary
at a future date.
Vent hose Ø 150 mm, or
125 mm Ø with reducing collar.