– Secure the exhaust socket to the va-
pour canopy with 4 screws.
– On EX model cooker hoods the con-
trol unit is fitted instead of the motor
unit and then secured with self lock-
ing nuts.
– Connect the 6 pole and the 15 pole
plugs from the vapour canopy into
the corresponding couplings on the
underside of the control unit.
– Connect the cooker hood to the ex-
ternal fan with the connecting cable
and the 6 pole plug.
26
– Fit the non-return flap supplied into
the exhaust socket in the motor unit
(this does not apply to EX models).
Non EX model cooker hoods are de-
signed to take ø 150 mm exhaust duct-
ing.
If ø 125 mm ducting has to be used the
reducing collar needs to be fitted into
the exhaust socket on the motor unit.
– For extraction connection secure a
flexible hose or an extraction pipe to
the exhaust socket of the motor unit
or to the vapour canopy using a
hose clip. Lead the top end through
the wall or ceiling cut-out.