Assigned power levels

The four cooker hood fan power levels
are selected according to the hob
power settings.
The values are for hobs with three, four,
five and six cooking zones.
Hobs with cooking zones which have
9 power settings
^ Fan power level "1":
At least one cooking zone is switched
on at a power setting of at least "1".
^ Fan power level "2":
Total of all power settings selected
= at least 4, where power setting "4"
has been selected for at least one of
the cooking zones.
^ Fan power level "3":
Total of all power settings selected
= at least 15 (17), where power
setting "6" has been selected for at
least one of the cooking zones.
^ Intensive setting:
Total of all power settings selected
= at least 25, where power setting "9"
has been selected for at least one of
the cooking zones.
(The values given in brackets refer to
HiLight hobs, if these differ)
Examples for fan power levels "1" to "4"
Hobs with cooking zones which have
12 power settings
^ Fan power level "1":
At least one cooking zone is switched
on at a power setting of at least "1".
^ Fan power level "2":
Total of all power settings selected
= at least 5, where one of the cooking
zones has a power setting of at least
"5".
^ Fan power level "3":
Total of all power settings selected
= at least 20 (23), where one of the
cooking zones has a power setting of
at least "8".
^ Intensive setting:
Total of all power settings selected
= at least 32, where one of the
cooking zones has a power setting of
at least "12" or the Booster function is
selected.
(The values given in brackets refer to
HiLight hobs, if these differ)
Examples for fan power levels "1" to "4"
The selection of the fan power level will
be delayed, see "Reaction time".
en - Operation