The tumble dryer can either be hard-wired or connected using a plug and socket
connection in accordance with IEC 60309-1. For a hard-wired connection, an all-pole
isolation device must be available at the installation site.
When in the off position, this all-pole isolation device ensures a 3 mm gap between all
open contacts. These include circuit breakers, fuses and relays (IEC/EN 60947).
If the mains supply cannot be permanently disconnected, the isolation device (including
plug and socket) must be safeguarded against being switched on either unintentionally or
without authorisation.
Useful tip: We recommend connecting the tumble dryer to the power supply via a plug
and socket so that it is easier to conduct electrical safety checks (e.g. during maintenance
or repair work).
The tumble dryer must not be connected to devices such as timers which would switch
it off automatically.
If the mains connection cable is damaged, it must be replaced by the manufacturer, its
service agent or similar qualified persons in order to avoid a hazard.
If it is necessary to install a residual current device (RCD) in accordance with local
regulations, a residual current device type B (sensitive to universal current) must be used.

Supply air/Exhaust air

The tumble dryer may only be operated when the ducting has been connected and the
room is sufficiently ventilated (see installation instructions).

Steam connection (only for steam-heated variants)

The steam connection must only be carried out by a registered installation technician. The
enclosed installation instructions must be observed as they are important for the steam
connection.

Hot water connection (only for hot water-heated variants)

The hot water connection may only be carried out by a registered installation technician.
The installation instructions must be observed as they are important for the hot water
connection.
If a tap is desired, it must be fitted on site.

Gas connection (only for gas-heated variants)

The gas connection must only be carried out by a registered installation technician in
accordance with the applicable national regulations (see installation instructions).
The gas heating is configured at the factory in line with the gas specifications on the
sticker on the rear of the appliance.
If the gas type is changed, a conversion kit must be requested from the Miele
Professional Service Department (please specify the appliance type, serial number, gas
type, gas group, gas connection pressure and country of installation). Follow the
installation instructions. This conversion may only be carried out by a registered specialist.
A gas appliance shall be installed such that the surface temperature of any nearby
combustible surface will not exceed 65 °C above ambient.