Miele T 1526 Technical Information - Page 20
Browse online or download pdf Technical Information for Dryer Miele T 1526. Miele T 1526 42 pages. Vented dryer
Also for Miele T 1526: Operation Manual (28 pages), Operation Manual (28 pages)
Technical Information
The condenser system draws air from outside the appliance via the condensate
fan (Item 8). The outside air passes through the heat exchanger in a 90° direction
from the drying air. The temperature difference between the two allows moisture
(condensation) to form on the heat exchanger. As the moisture level increases,
water droplets collect in a trough.
When the condensed water accumulates to a specific value, the condensate float
switch activates. The electronic switches on the condensate pump (Item 10) and
the water is pumped to the condensed-water drawer (Item 1). Should the
condensed-water drawer become full prior to the end of a cycle, the "Empty out
container" LED will light up and the program will stop.
Note:
Condenser dryers can be configured with an optional drain line. With this
configuration the condensed water is pumped directly into the drain, so
emptying the condensed-water drawer is not necessary.
4.3
Fan Motor (M5) Assembly
Figure 4-3: Fan Motor Assembly
1 Pulley/belts
2 Motor bracket
3 Motor start capacitor
4 Fan motor (120VAC)
5 Fan housing cover
6 Fan impeller
7 Fan housing
8 Motor assembly slide track
20
T 15xx Dryers