HP 315eu - Microtower PC Specifications - Page 7
Browse online or download pdf Specifications for Desktop HP 315eu - Microtower PC. HP 315eu - Microtower PC 21 pages. Support telephone numbers
Also for HP 315eu - Microtower PC: Getting Started (19 pages), Support List (34 pages)
QuickSpecs
System Details
Power Supply
Power Conservation
'Energy Saver'
System Environmental
Specs
ATX Power Supply - Passive PFC/non-PFC with a 115v/230v line switch
Passive Power Factor Correction (PFC) - with line switch set to 230V - No PFC in 115V line
switch position
90 to 140VAC, or 180 to 264VAC operating voltage range
100 to 127VAC, or 200 to 240VAC rated voltage range
50-60 Hz rated line frequency
47-63 Hz operating line frequency range
180 watt maximum rated power
80-mm power supply fan - variable speed for optimum acoustics
APM 1.2 support
Screen blanking
Hard drive 'Idle' mode
System Idle mode
~2 watt power consumption in ES mode - suspend to RAM (S3) (instantly available PC)
Processor/Cache memory power-down (S3)
Eup Lot 6 - less than 1W with BIOS setup option (Max power savings)
Values are subject to change without notification and are for reference only.
Performance of system, options, and ancillary equipment will vary depending on the system
configuration.
Levels presented do not account for non-HP/Compaq installed hardware.
Ambient Air
Temperature
Humidity
Altitude
Shock
Vibration
DA - 13686 Worldwide QuickSpecs — Version 3 — 7.23.2010
Operating
Storage
Operating
Storage
Operating
Non-Operating
Listed are the levels of shock the product can withstand with NO
damage being incurred. The values represent peak input acceleration
during a 2 to 3 ms half-sine shock pulse, 11 ms trapezoidal shock pulse.
Non-Operating
Listed are the levels of vibration the product can withstand with NO
damage being incurred. The values represent a flat random vibration
input acceleration profile across the given frequency range.
Compaq 315eu MT PC (EMEA only)
32° to 104° F (0° to 40° C) at sea level with an
altitude de-rating of 1.0°C per every 1000 ft
(300 m) above sea level to a maximum of
8000 ft (2500 m), no direct sustained sunlight.
Maximum rate of change is 77°F/Hr (25°C/Hr).
The upper limit may be limited by the type and
number of options installed.
-22° to 149° F (-30° to 65° C)
Maximum rate of change: 410°F/Hr
(210°C/Hr).
10% to 90% relative humidity (Rh), 86°F
(30°C) maximum wet bulb temperature, non-
condensing.
10% to 95% relative humidity (Rh), 101.66°F
(38.7°C) maximum wet bulb temperature,
non-condensing.
0 to 10,000 feet (0 to 3048 meters) - This
value may be limited by the type and number
of options installed. Maximum allowable
altitude change rate is 1,000 ft/min (304.8
m/min).
0 to 30,000 feet (0 to 9,144 meters) -
Maximum allowable altitude change rate is
1200 ft/min (365.76 m/min).
35G's (Half-sine Shock)
35G's (Trapezoidal Shock)
Page 7