Exhaust connection with a
flexible exhaust hose or rigid
pipe
Using the connector supplied, an
exhaust hose (4" [100 mm]
diameter) can be installed.
Necessary materials:
– a wall or window duct
(available from Miele)
– an exhaust hose made of approved
non-flammable material
^ Install the required connector*, 1,
with the exhaust hose or pipe, 2, to
the dryer.
* The white connector with clips is
used for connection to a hose; the
gray connector without clips is used
for connection to a pipe.
The exhaust duct must not be
connected or secured with screws
or other fastening devices which
extend into the interior of the duct.
Window connection
1 Window duct (installed in a
plexiglass pane)
2 Connector for the metallic flexible
exhaust hose
Wall connection with rigid pipe
1 Wall pipe (Installation sheet supplied
with the Miele wall pipe)
2 Connector
3 Rigid pipe