Miele CS 1122 Operating And Installation Instructions - Page 27

Browse online or download pdf Operating And Installation Instructions for Cooktop Miele CS 1122. Miele CS 1122 40 pages. Ceramic combiset
Also for Miele CS 1122: Operating And Installation Instructions (40 pages), Operating And Installation Manual (40 pages), Operating And Installation Instructions (40 pages), Operating And Installation Instructions (48 pages), User Manual (45 pages), Operating And Installation Instructions (40 pages)

Miele CS 1122 Operating And Installation Instructions
Safety distance from the wall covering
If a wall covering is installed, a minimum safety distance must be maintained
between the countertop cut-out and the covering, since high temperatures can
damage these materials.
If the covering is made of a combustible material (such as wood), the distance
between the countertop cut-out and the wall covering must be a minimum of
2" (50 mm).
For coverings made of non-combustible materials (such as metal, marble, granite
or ceramic tiles) the minimum safety distance
and the wall covering must be 2" (50 mm) minus the thickness of the covering.
For example: thickness of wall covering 9/16" (15 mm)
2" (50 mm) - 9/16" (15 mm) = minimum safety distance 1 3/8" (35 mm).
Wall frame
Wall covering
x = thickness of the wall covering
Countertop
Countertop cut-out
Minimum safety distance
with flammable materials 2" (50 mm)
with non-flammable materials 2" (50 mm) minus x
between the countertop cut-out

Installation

27