Miele GAS KM 81-2 Operating Instructions Manual - Page 18

Browse online or download pdf Operating Instructions Manual for Cooktop Miele GAS KM 81-2. Miele GAS KM 81-2 32 pages. Gas
Also for Miele GAS KM 81-2: Operating Instructions Manual (44 pages)

Miele GAS KM 81-2 Operating Instructions Manual
Electrical connection UK, IRL
Electrical connection UK, IRL
Electrical connection of the ap-
pliance should be undertaken by a
suitably competent person in strict
accordance with national and local
safety regulations.
The appliance is supplied with a mains
cable for connection to single phase
230-240 V, 50 Hz supply (GB), 220 V,
50 Hz (IRL). The fuse rating and rated
load are given on the data plate.
Connection should be made by a fused
connection unit or a switched socket
which complies with local and national
regulations and is accessible after the
appliance has been built-in.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA.
Important:
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings ident-
ifying the terminals in your plug, pro-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol z or col-
oured green or green and yellow.
18
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter L or coloured red.
WARNING
THIS APPLIANCE MUST BE
EARTHED.
Any replacement connection cable
must be 3 x 1 mm
2
.