Also for Miele KM 406: Operating Instructions Manual (20 pages), Dimension Manual (1 pages), Installation Instructions Manual (20 pages), Installation Instructions Manual (40 pages), Operating Instructions Manual (28 pages), Operating Instructions Manual (24 pages), Operating Instructions Manual (20 pages), Installation Instructions Manual (28 pages), Installation Instructions Manual (20 pages)

Miele KM 406 Installation Instructions Manual
KM 406
When converting to liquid gas, the
main jets and the small jets of all
burners must be changed.
Nominal rating at high setting
Burner
Nominal rating at low setting
Burner
Screw in the new jets according to the
following table.
Conversion to another type of gas
Gas type
MJ/h
NG
17.60
ULPG
17.40
Gas type
MJ/h
NG
0.65
ULPG
0.72

Jet table

For AUS and NZ
Main jet
Ø
NG
2.0
1.12
ULPG
The jet markings refer to 1/100 mm of
the jet orifice.
Low setting
jet Ø
0.90 / 0.40
Nr. 34
0.52 / 0.23
Nr. 7