MainTenance, TrOuBleshOOTing

Warning!
Risk of injury from improper maintenance.
▶ Maintenance may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart.
▶ Secure system from unintentional activation.
▶ Following maintenance, ensure a controlled restart.
6.1 Malfunctions
If malfunctions occur, check whether:
• the device has been installed according to the instructions,
• the electrical and fluid connections are correct,
• the device is not damaged,
• all screws have been tightened,
• the voltage and pressure have been switched on,
• the pipelines are clean,
• the power supply is adequately high.
Possible cause if the valve does not switch:
• Short circuit or coil interrupted.
• Inadequate power supply.
• Core or core area dirty.
• Medium pressure outside the permitted pressure range.
Possible cause if the valve does not close:
• Internal space of the valve is dirty.
If the valve still does not switch, please contact your Bürkert Service
representative.