Technical Data

Common
IEC Protection class
II
Ingress Protection
IP 20
Converter technology
Primary switching converter
Switching frequency
About 125 kHz
Power Factor Correction
Active PFC
Efficiency
≥ 85%
Temperature range
-10 ... 45 °C
It is not recommended to charge batteries
below an ambient temperature of 15 °C or
above 30 °C.
Ventilation
Fan
Input
Nominal voltage range
100 ... 240 V / 50 ... 60 Hz
Max. voltage range
90 ... 264 VAC / 47 ... 63 Hz
Max. input current
4.3 A
at 90 VAC and full-load of 300 W
at the output
Max. power
360 W
Fuse
4 AF
Technical Data
Output
Nominal / max. voltage
Max. output current
Fuse
Current regulation
Voltage regulation
Reverse current with the charger
switched off
Output voltage ripple
Output current ripple
Interface
USB
Mechanics
Weight
Dimensions (L x W x H)
24 / 35 VDC
10 ADC @ 30 VDC
15 AF
2 %
1 %
< 1 mA
< 100 mV
< 1% of the output current
USB 2.0, HID Class,
USB Mini B connector
About 1.7 kg
About 186 x 134 x 75 mm