Up-Dux® Ceiling-to-Attic Exhaust Vent - Installation Instructions (Extended Height Top-R™ Model)
PLEASE READ THE FOLLOWING INSTRUCTIONS IN THEIR ENTIRETY BEFORE STARTING INSTALLATION.
© 2010 Dial Manufacturing, Inc.
 Select installation location for Up-Dux®
vent. For best air circulation, vent should
be placed diagonally away from incoming
air register(s) and 18" to 24" away from
outer house wall (depending on the pitch of
the roof).
Drill a small hole within the selected
location, a few inches from the nearest
ceiling joist.
Use a probe (such as the straightened
end of a wire coat hanger) to make sure
that vent installation will avoid any
obstructions within the 20" minimum attic
clearance limit.
 Cut from the probe hole to the edge of –
but NOT into – the ceiling joist.
 Using the ceiling joist as a guide, make a
smooth 11-5/8" baseline cut along its
length. This baseline cut will be one side of
the vent opening. From each end of the
baseline cut, measure a distance of 11-5/8"
out and away from the ceiling joist.
 Using these measurements, scribe and
cut the remaining three sides of the square
11-5/8" x 11-5/8" vent opening.
 Locate the four "L" shaped mounting
clips that were included with the vent. Note
that these mounting clips have pre-drilled
holes that correspond to pre-drilled holes
on the front and back (hinge-end) panels of
the vent.
 Position and form each "L" shaped
mounting clip as follows: (a) place the edge
of the mounting clip exactly ½" away from
the corner of the ceiling opening and (b)
with the bottom of the "L" shaped clip held
firmly against the bottom of the ceiling
panel, press the top-edge of the mounting
clip forward and downward, bending the
clip around, and securing it to, the ceiling
panel.
Being careful not to damage the aluminum
lid, slide the vent into the ceiling opening –
with the hinged end toward the outside
house wall.
 Carefully align the pre-drilled holes on the
mounting clips with corresponding holes on
the vent's front and back (hinge-end)
panels.
 Insert the ¼" mounting clip screws to
secure the vent to the ceiling panel.
Use ½" grille mounting screws and pre-
drilled holes to mount the ceiling grille into
position on the vent.
IMPORTANT: DO NOT over-tighten the
mounting screws. Warping of the ceiling
grille frame caused by over-tightened
mounting screws may not be claimed
under warranty.
www.dialmfg.com