Alloy Home MH4 Manual - Page 9
Browse online or download pdf Manual for Thermostat Alloy Home MH4. Alloy Home MH4 12 pages. Electrical heating thermostat
Configuration of User Parameters (Hidden Menu)
In the shutdown interface, press
eters menu. Then, if applicable, input password 1234 using "Up" and "Down" buttons.
Press
to switch, then press the "Confirm" button to enter into the setting interface:
No.
Parameter
P1
High Temp Protection
P2
Room Temperature
Calibration
P3
Temperature Backlash
Value
P4
Key Volume Level
P5
Backlight Brightness
P6
Control Mode
P7
Time System
P8
Floor Temp Calibration
P9
Floor Temp Control
Backlash Value
and
Default
Range
45°C
OF/45°~95°
(113°F)
(113°-203°)
0 (00)
-9.5~9.5°C
(-16~16°F)
2°C (4°F)
0.5~10°C
(1-18°F)
3
OF/1~9
NO
NO/OF
A-F
A-F/Air/Flo
24
12/24
0 (00)
-9.5~9.5°C
(-16~16°F)
1.5°C
0.5~10°C
(3°F)
(01~18°F)
simultaneously to enter into the param-
OF: Turn off the floor high temp
1~9: Key Volume
OF: Backlight Energy Saving
Air: Ambient Room Temperature
Flo: Floor Temperature Control Mode
A/F: Room Temperature Control with
Floor High Temperature Limit Mode
12: 12-hour time system
24: 24-hour time system
Note
protection
OF: OFF
NO: Always on
Control Mode