Miller 029015507 Owner's Manual - Page 15

Browse online or download pdf Owner's Manual for Welding System Miller 029015507. Miller 029015507 40 pages.

Miller 029015507 Owner's Manual

3-4. Environmental Specifications

A. IP Rating
but is not intended to be used for welding outside during precipitation unless sheltered.
B. Temperature Specifications
Operating Temperature Range
14 to 104°F (−10 to 40°C)
C. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−volt-
age supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC61000-3-11 and IEC 61000−3−12 and can be connected to public low-voltage systems provided that the public
low-voltage system impedance Z
873,042.200 VA). It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator
if necessary, that the system impedance complies with the impedance restrictions.
Notes
This equipment is designed for outdoor use. It may be stored,
at the point of common coupling is less than 183 mW (or the short−circuit power S
max
IP Rating
IP23S
Storage Temperature Range
−4 to 131°F (−20 to 55°C)
IP23S 2014−06
Temp_2016- 07
is greater than
sc
ce-emc 1 2014-07
OM-274462 Page 9