5-2. Optional Auxiliary Power Receptacles
OM-403 Page 14
5
2
5
3
Y If unit does not have GFCI re-
.
1
Combined output of all receptacles
limited to 8 kVA/kW rating of the
generator.
GFCI Receptacle Option
1
GFCI2 and GFCI3 supply 60 Hz
single-phase power at weld/power
speed. Maximum output from
GFCI2 or GFCI3 is 2.4 kVA/kW.
Circuit breaker protection is the
same as standard receptacles.
If a ground fault is detected, the
GFCI Reset button pops out and
the circuit opens to disconnect the
faulty
4
damaged tools, cords, plugs, etc.
connected to the receptacle. Press
button to reset receptacle and
resume operation.
.
South African And Australian
Receptacle Options
2
3
Receptacles supply 60 Hz single-
phase power at weld/power speed.
Maximum output from each recep-
tacle is 3.6 kVA/kW.
4
4
CB1, CB2, and CB3 protect RC1,
RC2, and RC3 from overload. If a
circuit breaker opens, the recep-
tacle does not work. Press button to
reset breaker.
5
CB4 protects all the receptacles
from overload. If CB4 opens, none
of the receptacles work.
Ref. ST-178 079-A / Ref. ST-172 782-A / Ref. ST-172 113
ceptacles,
use
GFCI-
protected extension cord.
Auxiliary power decreases as
weld current increases.
Set Fine Adjust control R1 at 10
for full auxiliary power.
120 V 15 A AC GFCI Recep-
tacles GFCI2 And GFCI3
equipment.
Check
for
At least once a month, run
engine at weld/power speed
and press Test button to verify
GFCI is working properly.
240 V 16 A AC South African
Receptacles RC1, RC2, And
RC3
240 V 15 A AC Australian Re-
ceptacles RC1, RC2, And
RC3
Circuit Breakers CB1, CB2,
CB3