Miller Gold Seal 422 Owner's Manual - Page 18

Browse online or download pdf Owner's Manual for Welding System Miller Gold Seal 422. Miller Gold Seal 422 37 pages. Arc welding power source and wire feeder

Miller Gold Seal 422 Owner's Manual
SECTION 5 − MAINTENANCE &TROUBLESHOOTING

5-1. Routine Maintenance

3 Months
Replace
unreadable
labels.
6 Months
Blow out or
vacuum inside.
During heavy
service, clean
monthly.

5-2. Changing Drive Roll Or Wire Inlet Guide

2
Tools Needed:
OM-187 926 Page 16
Y Disconnect power before maintaining.
Repair or
replace
cracked
weld cable.
Or
1
Clean
and
tighten weld
terminals.
1
2
Loosen screw. Slide tip as close to
drive rolls as possible without
touching. Tighten screw.
3
3
Install drive roll, with correct groove
for wire size and type, facing in.
4
4
Secure drive roll with screw as
shown.
Inlet Wire Guide Securing
Screw
Inlet Wire Guide
Drive Roll
Drive Roll Securing Screw
Ref. ST-802 024